Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 173
Filter
1.
Korean Circulation Journal ; : 123-133, 2022.
Article in English | WPRIM | ID: wpr-917386

ABSTRACT

Background and Objectives@#Atherectomy as a pretreatment has the potential to improve the outcomes of drug-coated balloon (DCB) treatment by reducing and modifying atherosclerotic plaques. The present study investigated the outcomes of atherectomy plus DCB (A+DCB) compared with DCB alone for the treatment of femoropopliteal artery disease. @*Methods@#A total of 311 patients (348 limbs) underwent endovascular therapy using DCB for native femoropopliteal artery lesions at two endovascular centers. Of these, 82 limbs were treated with A+DCB and 266 limbs with DCB alone. After propensity score matching based on clinical and lesion characteristics, a total of 82 pairs was compared for immediate and mid-term outcomes. @*Results@#For the matched study groups, the lesion length was 172.7±111.2 mm, and severe calcification was observed in 43.3%. The technical success rate was higher in the A+DCB group than in the DCB group (80.5% vs. 62.2%, p=0.015). However, the A+DCB group showed more procedure-related minor complications (37.0% vs. 13.4%, p=0.047). At 2-year follow-up, primary clinical patency (73.8% vs. 82.6%, p=0.158) and the target lesion revascularization (TLR)-free survival (84.3% vs. 88.2%, p=0.261) did not differ between the two groups. In Cox proportional hazard analysis, atherectomy showed no significant impact on the outcome of DCB treatments. @*Conclusions@#The pretreatment with atherectomy improved technical success of DCB treatment; however, it was associated with increased minor complications. In this study, A+DCB showed no clinical benefit in terms of TLR-free survival or clinical patency compared with DCB treatment alone.

2.
Korean Circulation Journal ; : 324-337, 2022.
Article in English | WPRIM | ID: wpr-926511

ABSTRACT

Background and Objectives@#Identifying patients with high bleeding risk (HBR) is important when making decisions for antiplatelet therapy strategy. This study evaluated the impact of ticagrelor monotherapy after 3-month dual antiplatelet therapy (DAPT) according to HBR in acute coronary syndrome (ACS) patients treated with drug eluting stents (DESs). @*Methods@#In this post-hoc analysis of the TICO trial, HBR was defined by 2 approaches: meeting Academic Research Consortium for HBR (ARC-HBR) criteria or Predicting Bleeding Complications in Patients Undergoing Stent Implantation and Subsequent DAPT (PRECISEDAPT) score ≥25. The primary outcome was a 3–12 months net adverse clinical event (composite of major bleeding and adverse cardiac and cerebrovascular events). @*Results@#Of the 2,980 patients without adverse events during the first 3 months after DES implantation, 453 (15.2%) were HBR by ARC-HBR criteria and 504 (16.9%) were HBR by PRECISE-DAPT score. The primary outcome rate was higher in HBR versus non-HBR patients (by ARC-HBR criteria: hazard ratio [HR], 2.87; 95% confidence interval [CI], 1.76– 4.69; p<0.001; by PRECISE-DAPT score: HR, 3.09; 95% CI, 1.92–4.98; p<0.001). Ticagrelor monotherapy after 3-month DAPT was associated with lower primary outcome rate than ticagrelor-based 12-month DAPT regardless of HBR by ARC-HBR criteria, with similar magnitudes of therapy effect for HBR and non-HBR patients (p-interaction=0.400). Results were consistent by PRECISE-DAPT score (p-interaction=0.178). @*Conclusions@#In ACS patients treated with DESs, ticagrelor monotherapy after 3-month DAPT was associated with lower rate of adverse clinical outcomes regardless of HBR, with similar magnitudes of therapy effect between HBR and non-HBR.Trial Registration: ClinicalTrials.gov Identifier: NCT02494895

3.
Yonsei Medical Journal ; : 885-894, 2021.
Article in English | WPRIM | ID: wpr-904291

ABSTRACT

Purpose@#This study sought to compare clinical outcomes between transcatheter aortic valve replacement (TAVR) and sutureless aortic valve replacement (SU-AVR). @*Materials and Methods@#In total, 320 patients with symptomatic severe aortic stenosis who underwent TAVR (n=254) or SU-AVR (n=66) at Severance Cardiovascular Hospital between July 2011 and September 2019 were included for analysis. Propensity score matching and inverse probability weighted adjustment were performed to adjust for confounding baseline characteristics. Outcomes defined by the Valve Academic Research Consortium-2 in 62 patients pairs were compared. @*Results@#Device success (79.0% vs. 79.0%, p>0.999) and 30-day mortality (4.8% vs. 0.0%, p=0.244) did not differ between the TAVR and SU-AVR groups. The TAVR group developed more frequent mild or moderate paravalvular leakage (59.7% vs. 8.1%, p<0.001), whereas SU-AVR was associated with higher rates of major or life-threatening bleeding (9.7% vs. 22.6%, p=0.040), acute kidney injury (8.1% vs. 21.0%, p=0.041), and new-onset atrial fibrillation (4.8% vs. 32.3%. p<0.001) at 30 days, along with longer stays in the intensive care unit (ICU) (1.9±1.6 days vs. 5.9±9.2 days, p=0.009) and hospital (7.1±7.9 days vs. 13.1±8.8 days, p<0.001). The TAVR group showed a trend towards a higher 1-year all-cause mortality, compared with the SU-AVR group (7.0% vs 1.7%, p=0.149). Cardiovascular mortality, however, did not differ significantly (1.6% vs 1.7%, p=0.960). @*Conclusion@#TAVR achieved a similar 1-year survival rate free from cardiovascular mortality as SU-AVR and was associated with a lower incidence of complications, except for paravalvular leakage, and shorter stays in the ICU and hospital.

4.
Yonsei Medical Journal ; : 990-996, 2021.
Article in English | WPRIM | ID: wpr-904278

ABSTRACT

Purpose@#Concerns have been consistently raised in regards to the considerable amount of contrast dye used during transcatheter aortic valve replacement (TAVR) in patients with renal insufficiency. In the present study, we introduced minimal contrast TAVR and compared its 30-day clinical outcomes with conventional TAVR. @*Materials and Methods@#We retrospectively investigated 369 patients who underwent TAVR between July 2011 and April 2020 in our institute. Among them, 93 patients with severe aortic stenosis and renal insufficiency (estimated glomerular filtration rate ≤50 mL/min/1.73 m2 ) were included and divided into a conventional TAVR group (n=56) and a minimal contrast TAVR group (n=37). In the minimal contrast TAVR group, the total amount of contrast was <10 mL during the entire TAVR procedure. Thirty-day major adverse clinical events (MACE), including death, stroke, implantation of permanent pacemaker, and initiation of hemodialysis, were investigated. @*Results@#The incidence of MACE was significantly lower in the minimal contrast TAVR group than the conventional TAVR group (16.2% vs. 42.9%, p=0.010). Death occurred in 9 patients (16.1%) in the conventional TAVR group and in 0 patients in the minimal contrast group (p=0.011). Hemodialysis was initiated in 2 patients (5.4%) in the minimal contrast TAVR group and in 7 patients (12.5%) in the conventional TAVR group (p=0.256). Multivariate regression analysis showed that the minimal contrast TAVR procedure was an independent predictor for reducing MACE (hazard ratio 0.208, 95% confidence interval: 0.080–0.541, p=0.001). @*Conclusion@#Minimal contrast TAVR is feasible and shows more favorable short-term clinical outcomes than conventional TAVR in patients with renal insufficiency.

5.
Korean Circulation Journal ; : 222-231, 2021.
Article in English | WPRIM | ID: wpr-901647

ABSTRACT

Background and Objectives@#Transcatheter aortic valve replacement (TAVR) has been reported as a good alternative for surgical aortic valve replacement in patients with small aortic annulus. Head-to-head comparisons of different transcatheter aortic valves in these patients are insufficient. We compared the outcomes after TAVR between two different types of recent transcatheter aortic valves (self-expanding vs. balloon-expandable) in patients with small aortic annulus. @*Methods@#A total of 70 patients with severe aortic stenosis and small annulus (mean diameter ≤23 mm or minimal diameter ≤21 mm on computed tomography) underwent TAVR with either a self-expanding valve with supra-annular location (n=45) or a balloon-expandable valve with intra-annular location (n=25). The echocardiographic hemodynamic parameters after TAVR and 1-year follow-up were compared. @*Results@#Between the self-expanding and balloon-expandable valve-treated patients, the clinical outcomes including permanent pacemaker implantation (11.1% vs. 8.0%), acute kidney injury stage 2 or 3 (4.4% vs. 4.0%), and major vascular complication (4.4% vs. 0.0%) were similar without all-cause mortality, stroke, and life-threatening bleeding during 30-day follow-up. Compared with the balloon-expandable valve-treated patients, the self-expanding valve-treated patients presented larger effective orifice area (EOA) (1.46±0.28 vs. 1.75±0.42 cm2 , p=0.002) and indexed EOA (0.95±0.21 vs. 1.18±0.28 cm2 /m2 , p=0.001), whereas mean aortic valve gradient (11.7±2.9 vs. 8.9±5.2 mmHg, P=0.005) and incidence of ≥moderate prosthesis-patient mismatch (36.0% vs. 8.9%, p=0.009) were lower. These hemodynamic differences were maintained at 1-year follow-up. @*Conclusions@#TAVR with self-expanding valves was associated with superior hemodynamic outcomes compared with balloon-expandable valves in patients with small aortic annulus.

6.
Yonsei Medical Journal ; : 885-894, 2021.
Article in English | WPRIM | ID: wpr-896587

ABSTRACT

Purpose@#This study sought to compare clinical outcomes between transcatheter aortic valve replacement (TAVR) and sutureless aortic valve replacement (SU-AVR). @*Materials and Methods@#In total, 320 patients with symptomatic severe aortic stenosis who underwent TAVR (n=254) or SU-AVR (n=66) at Severance Cardiovascular Hospital between July 2011 and September 2019 were included for analysis. Propensity score matching and inverse probability weighted adjustment were performed to adjust for confounding baseline characteristics. Outcomes defined by the Valve Academic Research Consortium-2 in 62 patients pairs were compared. @*Results@#Device success (79.0% vs. 79.0%, p>0.999) and 30-day mortality (4.8% vs. 0.0%, p=0.244) did not differ between the TAVR and SU-AVR groups. The TAVR group developed more frequent mild or moderate paravalvular leakage (59.7% vs. 8.1%, p<0.001), whereas SU-AVR was associated with higher rates of major or life-threatening bleeding (9.7% vs. 22.6%, p=0.040), acute kidney injury (8.1% vs. 21.0%, p=0.041), and new-onset atrial fibrillation (4.8% vs. 32.3%. p<0.001) at 30 days, along with longer stays in the intensive care unit (ICU) (1.9±1.6 days vs. 5.9±9.2 days, p=0.009) and hospital (7.1±7.9 days vs. 13.1±8.8 days, p<0.001). The TAVR group showed a trend towards a higher 1-year all-cause mortality, compared with the SU-AVR group (7.0% vs 1.7%, p=0.149). Cardiovascular mortality, however, did not differ significantly (1.6% vs 1.7%, p=0.960). @*Conclusion@#TAVR achieved a similar 1-year survival rate free from cardiovascular mortality as SU-AVR and was associated with a lower incidence of complications, except for paravalvular leakage, and shorter stays in the ICU and hospital.

7.
Yonsei Medical Journal ; : 990-996, 2021.
Article in English | WPRIM | ID: wpr-896574

ABSTRACT

Purpose@#Concerns have been consistently raised in regards to the considerable amount of contrast dye used during transcatheter aortic valve replacement (TAVR) in patients with renal insufficiency. In the present study, we introduced minimal contrast TAVR and compared its 30-day clinical outcomes with conventional TAVR. @*Materials and Methods@#We retrospectively investigated 369 patients who underwent TAVR between July 2011 and April 2020 in our institute. Among them, 93 patients with severe aortic stenosis and renal insufficiency (estimated glomerular filtration rate ≤50 mL/min/1.73 m2 ) were included and divided into a conventional TAVR group (n=56) and a minimal contrast TAVR group (n=37). In the minimal contrast TAVR group, the total amount of contrast was <10 mL during the entire TAVR procedure. Thirty-day major adverse clinical events (MACE), including death, stroke, implantation of permanent pacemaker, and initiation of hemodialysis, were investigated. @*Results@#The incidence of MACE was significantly lower in the minimal contrast TAVR group than the conventional TAVR group (16.2% vs. 42.9%, p=0.010). Death occurred in 9 patients (16.1%) in the conventional TAVR group and in 0 patients in the minimal contrast group (p=0.011). Hemodialysis was initiated in 2 patients (5.4%) in the minimal contrast TAVR group and in 7 patients (12.5%) in the conventional TAVR group (p=0.256). Multivariate regression analysis showed that the minimal contrast TAVR procedure was an independent predictor for reducing MACE (hazard ratio 0.208, 95% confidence interval: 0.080–0.541, p=0.001). @*Conclusion@#Minimal contrast TAVR is feasible and shows more favorable short-term clinical outcomes than conventional TAVR in patients with renal insufficiency.

8.
Yonsei Medical Journal ; : 209-214, 2021.
Article in English | WPRIM | ID: wpr-875617

ABSTRACT

Purpose@#Acute coronary occlusion is a rare but fatal complication that may occur during trans-catheter aortic valve implantation (TAVI) and appears more frequently in patients with low coronary heights. We evaluated the feasibility of self-expanding valves in patients with low coronary heights undergoing TAVI. @*Materials and Methods@#TAVI for native aortic valve stenosis was conducted in 276 consecutive patients between 2015 and 2019 at our institute. Using multi-detector computed tomography (MDCT), information on the aortic valve, coronary arteries, and vascular anatomy in 269 patients was analyzed. Patients with low coronary heights were defined as those with coronary heights of 10 mm or less during MDCT analysis. @*Results@#Among the 269 patients, 29 (10.8%) patients had coronary arteries with low heights. The mean coronary height was 8.9±1.2 mm in the left coronary artery. These patients with low coronary heights were treated with self-expandable (n=28) or balloon-expandable (n=1) valves. Prophylactic coronary protection with a guidewire, balloon, or stent prepositioned down at-risk coronary arteries was not pursued in all patients. No acute coronary occlusion occurred in any of these patients during TAVI. Five patients (17.9%) died during follow-up (average of 553.8 days), including four from non-cardiogenic causes and one from a cardiogenic (aggravation of heart failure) cause. @*Conclusion@#A considerable number of patients with low coronary heights were observed among TAVI candidates in this study. Use of a self-expandable valve may be feasible for successful TAVI without acute coronary occlusion in patients with low coronary heights.

9.
Korean Circulation Journal ; : 222-231, 2021.
Article in English | WPRIM | ID: wpr-893943

ABSTRACT

Background and Objectives@#Transcatheter aortic valve replacement (TAVR) has been reported as a good alternative for surgical aortic valve replacement in patients with small aortic annulus. Head-to-head comparisons of different transcatheter aortic valves in these patients are insufficient. We compared the outcomes after TAVR between two different types of recent transcatheter aortic valves (self-expanding vs. balloon-expandable) in patients with small aortic annulus. @*Methods@#A total of 70 patients with severe aortic stenosis and small annulus (mean diameter ≤23 mm or minimal diameter ≤21 mm on computed tomography) underwent TAVR with either a self-expanding valve with supra-annular location (n=45) or a balloon-expandable valve with intra-annular location (n=25). The echocardiographic hemodynamic parameters after TAVR and 1-year follow-up were compared. @*Results@#Between the self-expanding and balloon-expandable valve-treated patients, the clinical outcomes including permanent pacemaker implantation (11.1% vs. 8.0%), acute kidney injury stage 2 or 3 (4.4% vs. 4.0%), and major vascular complication (4.4% vs. 0.0%) were similar without all-cause mortality, stroke, and life-threatening bleeding during 30-day follow-up. Compared with the balloon-expandable valve-treated patients, the self-expanding valve-treated patients presented larger effective orifice area (EOA) (1.46±0.28 vs. 1.75±0.42 cm2 , p=0.002) and indexed EOA (0.95±0.21 vs. 1.18±0.28 cm2 /m2 , p=0.001), whereas mean aortic valve gradient (11.7±2.9 vs. 8.9±5.2 mmHg, P=0.005) and incidence of ≥moderate prosthesis-patient mismatch (36.0% vs. 8.9%, p=0.009) were lower. These hemodynamic differences were maintained at 1-year follow-up. @*Conclusions@#TAVR with self-expanding valves was associated with superior hemodynamic outcomes compared with balloon-expandable valves in patients with small aortic annulus.

11.
Yonsei Medical Journal ; : 851-859, 2020.
Article | WPRIM | ID: wpr-833398

ABSTRACT

Purpose@#Thrombocytopenia (platelet count <150×103 /μL) is associated with poor outcomes in various critical illness settings. However, the prognostic value of platelet count in patients with cardiogenic shock (CS) remains unclear. @*Materials and Methods@#We enrolled 1202 patients between January 2014 and December 2018 from a multicenter retrospective– prospective cohort registry of CS. Clinical characteristics and treatment outcomes were compared between the patients with and without thrombocytopenia. @*Results@#At presentation with CS, 244 (20.3%) patients had thrombocytopenia. The patients with thrombocytopenia had lower blood pressure, hemoglobin level, and worse liver and renal functions compared to the patients without. During hospitalization, the patients with thrombocytopenia had more frequent gastrointestinal bleeding (10.5% vs. 3.8%, p=0.009), sepsis (8.3% vs. 2.6%, p=0.013), requirement of renal replacement therapy (36.5% vs. 18.9%, p<0.001), requirement of mechanical ventilation (65.2% vs.54.4%, p=0.003), longer intensive care unit stay (8 days vs. 4 days, p<0.001), and thirty-day mortality (40.2% vs. 28.5%, p<0.001) compared to those without. In addition, the platelet count was an independent predictor of 30-day mortality (per 103 /µL decrease; adjusted hazard ratio: 1.002, 95% confidence interval: 1.000–1.003, p=0.021). @*Conclusion@#Thrombocytopenia at CS presentation was associated with worse clinical findings, higher frequencies of complications, and longer stay at the intensive care unit. Also, thrombocytopenia was independently associated with increased 30-day mortality.(Clinical trial registration No. NCT02985008).

12.
Yonsei Medical Journal ; : 597-605, 2020.
Article | WPRIM | ID: wpr-833347

ABSTRACT

Purpose@#Although current guidelines recommend the administration of dual antiplatelet therapy (DAPT) for up to 12 months after the implantation of a drug-eluting stent (DES), extended DAPT is frequently used in real-world practice. @*Materials and Methods@#From the Korean Multicenter Angioplasty Team registry, we identified a total of 1414 patients who used DAPT for >3 years after DES implantation (extended-DAPT group) and conducted a landmark analysis at 36 months after the index procedure. We evaluated the determinants for and long-term outcomes of extended DAPT and compared the occurrence of major adverse cardiovascular and cerebrovascular events (MACCE), defined as the composite of all-cause death, myocardial infarction, stent thrombosis, and stroke, between the extended-DAPT group and the guideline-DAPT group [DAPT <1 year after DES implantation (n=1273)]. @*Results@#Multivariate analysis indicated the occurrence of acute coronary syndrome as the most significant clinical determinant of the use of extended DAPT. Bifurcation, stent diameter ≤3.0 mm, total stented length ≥28 mm, and use of first-generation DESs were also significant angiographic and procedural determinants. MACCE rates were similar between the extended-DAPT group and the guideline-DAPT group in crude analysis [hazard ratio (HR), 1.08; 95% confidence interval (CI), 0.69–1.68; p=0.739] and after propensity matching (HR, 1.22; 95% CI, 0.72–2.07; p=0.453). Major bleeding rates were comparable between the two groups. @*Conclusion@#In patients undergoing percutaneous coronary intervention, indefinite use of DAPT does not show superior outcomes to those of guideline-DAPT. Major bleeding rates are also similar.

13.
Korean Circulation Journal ; : 880-889, 2020.
Article | WPRIM | ID: wpr-833072

ABSTRACT

Previous pathologic, intravascular imaging, and clinical studies have investigated the association between adverse cardiac events and stent malapposition, including acute stent malapposition (ASM, that is detected at index procedure) and late stent malapposition (LSM, that is detected during follow-up) that can be further classified into late-persistent stent malapposition (LPSM, ASM that remains at follow-up) or late-acquired stent malapposition (LASM, newly developed stent malapposition at follow-up that was not present immediately after index stent implantation). ASM has not been associated with adverse cardiac events compared with non-ASM, even in lesions with large-sized malapposition. The clinical outcomes of LSM may depend on its subtype. The recent intravascular ultrasound studies with long-term follow-up have consistently demonstrated that LASM steadily increased the risk of thrombotic events in patients with first-generation drug-eluting stents (DESs). This association has not yet been identified in LPSM. Accordingly, it is reasonable that approaches to stent malapposition should be based on its relationship with clinical outcomes. ASM may be tolerable after successful stent implantation, whereas prolonged anti-thrombotic medications and/or percutaneous interventions to modify LASM may be considered in selected patients with first-generation DESs. However, these treatments are still questionable due to lack of firm evidences.

14.
Korean Circulation Journal ; : 443-457, 2020.
Article in English | WPRIM | ID: wpr-833044

ABSTRACT

BACKGROUND AND OBJECTIVES@#We sought to investigate an anti-atherosclerotic and anti-inflammatory effect of sodium-glucose cotransporter-2 (SGLT-2) inhibitors in normoglycemic atherosclerotic rabbit model.@*METHODS@#Male New Zealand white rabbits (n=26) were fed with a 1% high-cholesterol diet for 7 weeks followed by normal diet for 2 weeks. After balloon catheter injury, the rabbits were administered with the Dapagliflozin (1mg/kg/day) or control-medium for 8 weeks (n=13 for each group). All lesions were assessed with angiography, optical coherence tomography (OCT), and histological assessment.@*RESULTS@#Atheroma burden (38.51±3.16% vs. 21.91±1.22%, p<0.01) and lipid accumulation (18.90±3.63% vs. 10.20±2.03%, p=0.047) was significantly decreased by SGLT-2 inhibitor treatment. The SGLT-2 inhibitor group showed lower macrophage infiltration (20.23±1.89% vs. 12.72±1.95%, p=0.01) as well as tumor necrosis factor (TNF)-α expression (31.17±4.40% vs. 19.47±2.10%, p=0.025). Relative area of inducible nitric oxide synthase+ macrophages was tended to be lower in the SGLT-2 inhibitor-treated group (1.00±0.16% vs. 0.71±0.10%, p=0.13), while relative proportion of Arg1⁺ macrophage was markedly increased (1.00±0.27% vs. 2.43±0.64%, p=0.04). As a result, progression of atherosclerosis was markedly attenuated in SGLT-2 inhibitor treated group (OCT area stenosis, 32.13±1.20% vs. 22.77±0.88%, p<0.01). Mechanistically, SGLT-2 treatment mitigated the inflammatory responses in macrophage. Especially, Toll-like receptor 4uclear factor-kappa B signaling pathway, and their downstream effectors such as interleukin-6 and TNF-α were markedly suppressed by SGLT-2 inhibitor treatment.@*CONCLUSIONS@#These results together suggest that SGLT-2 inhibitor exerts an anti-atherosclerotic effect through favorable modulation of inflammatory response as well as macrophage characteristics in non-diabetic situation.

15.
Korean Circulation Journal ; : 499-508, 2020.
Article | WPRIM | ID: wpr-833025

ABSTRACT

Background and Objectives@#Whether beta blockers favorably impact the clinical outcome in patients with acute myocardial infarction (AMI) remains in debate. We investigated the impact of beta blocker on major clinical outcomes during 2 years after percutaneous coronary intervention (PCI) in patients with AMI. @*Methods@#All patients with the first AMI treated with PCI for the period of 2005 to 2014 from the Korean National Health Insurance Service claims database were enrolled. We defined the regular user as medication possession ratio (MPR) ≥80% and non-user as MPR=0%. We compared the occurrence of all cause death, myocardial infarction (MI) and stroke according to adherence of beta-blockers. A 1:1 propensity score-matching was conducted to adjust for between-group differences. @*Results@#We identified a total 81,752 patients with met eligible criteria. At discharge, 63,885 (78%) patients were prescribed beta blockers. For 2 years follow up period, regular users were 53,991 (66%) patients, non-users were 10,991 (13%). In the propensity score matched population, regular use of beta blocker was associated with a 36% reduced risk of composite adverse events (all death, MI or stroke) (hazard ratio [HR], 0.636; 95% confidence interval [CI], 0.555–0.728; p<0.001). Compared to no use of beta blocker, regular use significantly reduced all death (HR, 0.736; 95% CI, 0.668–0.812; p<0.001), MI (HR, 0.729; 95% CI, 0.611–0.803; p<0.001) and stroke (HR, 0.717; 95% CI, 0.650–0.791; p<0.001). @*Conclusions@#Prescription of beta blocker in patients with AMI after PCI was sequentially increased. Continuous regular use of beta blocker for 2 years after AMI reduced major adverse events compared to no use of beta blocker.

16.
Korean Circulation Journal ; : 443-457, 2020.
Article in English | WPRIM | ID: wpr-816671

ABSTRACT

BACKGROUND AND OBJECTIVES: We sought to investigate an anti-atherosclerotic and anti-inflammatory effect of sodium-glucose cotransporter-2 (SGLT-2) inhibitors in normoglycemic atherosclerotic rabbit model.METHODS: Male New Zealand white rabbits (n=26) were fed with a 1% high-cholesterol diet for 7 weeks followed by normal diet for 2 weeks. After balloon catheter injury, the rabbits were administered with the Dapagliflozin (1mg/kg/day) or control-medium for 8 weeks (n=13 for each group). All lesions were assessed with angiography, optical coherence tomography (OCT), and histological assessment.RESULTS: Atheroma burden (38.51±3.16% vs. 21.91±1.22%, p<0.01) and lipid accumulation (18.90±3.63% vs. 10.20±2.03%, p=0.047) was significantly decreased by SGLT-2 inhibitor treatment. The SGLT-2 inhibitor group showed lower macrophage infiltration (20.23±1.89% vs. 12.72±1.95%, p=0.01) as well as tumor necrosis factor (TNF)-α expression (31.17±4.40% vs. 19.47±2.10%, p=0.025). Relative area of inducible nitric oxide synthase+ macrophages was tended to be lower in the SGLT-2 inhibitor-treated group (1.00±0.16% vs. 0.71±0.10%, p=0.13), while relative proportion of Arg1⁺ macrophage was markedly increased (1.00±0.27% vs. 2.43±0.64%, p=0.04). As a result, progression of atherosclerosis was markedly attenuated in SGLT-2 inhibitor treated group (OCT area stenosis, 32.13±1.20% vs. 22.77±0.88%, p<0.01). Mechanistically, SGLT-2 treatment mitigated the inflammatory responses in macrophage. Especially, Toll-like receptor 4/nuclear factor-kappa B signaling pathway, and their downstream effectors such as interleukin-6 and TNF-α were markedly suppressed by SGLT-2 inhibitor treatment.CONCLUSIONS: These results together suggest that SGLT-2 inhibitor exerts an anti-atherosclerotic effect through favorable modulation of inflammatory response as well as macrophage characteristics in non-diabetic situation.


Subject(s)
Humans , Male , Rabbits , Angiography , Atherosclerosis , Catheters , Constriction, Pathologic , Diet , Interleukin-6 , Macrophages , Nitric Oxide , Plaque, Atherosclerotic , Toll-Like Receptors , Tomography, Optical Coherence , Tumor Necrosis Factor-alpha
18.
Korean Circulation Journal ; : 283-297, 2019.
Article in English | WPRIM | ID: wpr-759429

ABSTRACT

Transcatheter aortic valve implantation (TAVI) has been accepted as one of primary options for treatment of symptomatic severe aortic stenosis. Although TAVI has been predominantly used for patients at high risk or with old age who were not considered optimal candidates for surgical aortic valve replacement (SAVR), its indication is now expanding toward low risk profile and younger age. Many clinical trials are now ongoing to test the possibility of TAVI for use in patients even with uncharted indications who are not eligible for SAVR in current guidelines but may benefit from valve replacement. Current issues including periprocedural safety, long-term adverse events, hemodynamics and durability associated with TAVI should be also solved for expanding use of TAVI. The review presents current status and future directions of TAVI and discusses perspectives in Korea.


Subject(s)
Humans , Aortic Valve , Aortic Valve Stenosis , Hemodynamics , Korea , Transcatheter Aortic Valve Replacement
19.
Yonsei Medical Journal ; : 824-831, 2019.
Article in English | WPRIM | ID: wpr-762124

ABSTRACT

PURPOSE: We evaluated the incidence, predictors, and prognosis of coronary artery aneurysm (CAA) after second-generation drug-eluting stent (DES) implantation. MATERIALS AND METHODS: A total of 976 consecutive patients (1245 lesions) who underwent follow-up angiography after second-generation DES implantation were analyzed. Incidence and predictors of CAA were assessed, and clinical prognosis was compared with 34 cases of CAA after first-generation DES implantation using previous CAA registry data. RESULTS: All 10 cases of CAA (0.80% per lesion) in 10 patients (1.02% per patient) were detected at follow up. Compared to lesions without CAA, those with CAA had greater involvement of the proximal segment (90% vs. 51%, p=0.014), a higher proportion of pre-intervention, a Thrombolysis in Myocardial Infarction score of 0 or 1 flow (80% vs. 16%, p<0.001), more chronic total occlusions (40% vs. 10%, p<0.001), and longer implanted stents (41.9±23.2 mm vs. 28.8±14.8 mm, p=0.006). As for CAA morphology, instances of CAA after second-generation DES were predominantly the single fusiform type (90%), whereas instances of CAA after first-generation DES were multiple saccular (47%) and single saccular (35%) types (p<0.001). Myocardial infarction with stent thrombosis occurred in 5 patients with CAA after first-generation DES (15%), and no adverse events were observed in patients with CAA after second-generation DES over a median follow-up duration of 4.3 years (p=0.047, log-rank). CONCLUSION: Although CAAs after second-generation DES implantation were detected at a similar incidence to that for CAAs after first-generation DES implantation, second-generation DES-related CAAs had different morphologies and more benign clinical outcomes versus first-generation DES-related CAAs.


Subject(s)
Humans , Aneurysm , Angiography , Coronary Artery Disease , Coronary Vessels , Drug-Eluting Stents , Follow-Up Studies , Incidence , Myocardial Infarction , Percutaneous Coronary Intervention , Prognosis , Stents , Thrombosis
20.
Yonsei Medical Journal ; : 1108-1111, 2019.
Article in English | WPRIM | ID: wpr-762047

ABSTRACT

The primary concern in percutaneous coronary intervention for bifurcation lesions is occlusion of a side branch after stenting of a main branch, especially in high-risk patients. We describe a novel technique, consecutive jailed- and kissing-Corsair technique, using a Corsair microcatheter for protection of side branches in bifurcation lesions.


Subject(s)
Humans , Percutaneous Coronary Intervention , Stents
SELECTION OF CITATIONS
SEARCH DETAIL